Technical advantages
●The single line lubrication system has reliable performance and l☆ow operation and maintenance costs;
●The gearbox and generator adopt a natural air cooling system, which has low self power consumption¶, low failure rate, and low noise;
●Advanced load optimization control technology significantly reduce∏s the load on the entire machine and key componentsε, improving reliability;
●Better intelligent pitch control, refined yaw control, intelligent soft c<utting control, and adaptive environment
●Better intelligent control technologies such as dynamic energy capture and grid o§ptimization control, to fully tap into the potential of power generatio©n,
●Improve the power generation efficiency and environmental adaptability of th€e unit, and achieve maximum customer benefits;
●Customizable online detection and monitoring system, intelligent fault self ≥diagnosis and operation optimization technology, wind power
●Advanced technologies such as machine information sharing tec hnology, intelligent debugging and defect elimination platform for wind turbines, etc., brin g users
●Higher reliability and availability;
FEATURES
●Variable pitch system
Supercapacitors serve as backup power sources, with low temperature resistance and fast response sp≤eed;
The pitch control system is installed inside the wheel hub, with good lightning protecβtion and sealing effects.
●Leaves
High strength fiberglass blades are used, and wear-resistant measur♥es are taken at the leading edge of the blades;
Reliable blade lightning protection.
●Automatic lubrication system
The variable pitch system, yaw system, and main beari®ngs adopt automatic lubrication to reduce maintenance time and fr↑equency, and lower maintenance costs
●Gearbox
Adopting oil-water heat exchanger, with high heat transfer efficiency and good low-tempera→ture start-up performance;
The offline fine filtration system ensures the performance of oil products an d extends their service life.
Natural air cooling system
The gearbox and generator adopt a natural air cooling∏ system, which consumes less power, produces less noise, has a low failure rate, and requi±res less maintenance.
●Generator
Air cooled generator, small in size and light in weight;
The generator adopts insulated end caps and multi-point grounding technology to elimiπnate shaft current.
●Repair the sunroof
Lifting the generator does not require dismantling the en•gine compartment cover, making it easy to open and close and operate.
●Frequency converter
The frequency converter is located at the tower base and adopts air cooling for reliable← operation and easy maintenance.
●Repair the crane
The lifting capacity is 600kg, and the maintenance range covers the entire cabin space.
●Noise reduction device
The gearbox is equipped with rubber elastic units as noise reduction devices, which are simple, reliable, and easy to maintain.
Technical Data